Steel Source Australia
Insulation & Thermal

Insulated
Roofing

A complete range of insulation products for metal roofing and wall systems — from Anticon blankets and Soundscreen acoustic insulation to factory-laminated PIR/PUR insulated panels, glasswool batts and reflective foil sarking. All products NCC energy compliance ready.

9 product categories
74+ individual SKUs
NCC energy compliance ready
Bulk & project pricing available

NCC Minimum R-Values by Climate Zone

(NCC 2022 — Class 1 & 10 buildings)
Zone 1 (Tropical)
Roof: R1.5
Wall: R1.5
Zone 2 (Sub-tropical)
Roof: R2.0
Wall: R1.5
Zone 3 (Warm)
Roof: R2.5
Wall: R1.5
Zone 4 (Mixed)
Roof: R3.5
Wall: R2.0
Zone 5 (Cool)
Roof: R4.1
Wall: R2.8
Zone 6 (Cold)
Roof: R5.1
Wall: R3.8
Zone 7 (Very Cold)
Roof: R6.3
Wall: R5.1
Zone 8 (Alpine)
Roof: R7.5
Wall: R6.3

Minimum total R-values for roofs and walls. Actual requirements vary by building class, climate zone and construction type — consult your certifier or energy assessor.

Anticon is a glasswool blanket with a reflective foil facing, designed to be installed directly under metal roofing sheets. It provides thermal insulation, condensation control and acoustic dampening in one product. Available in a range of thicknesses and R-values to suit residential, commercial and industrial applications.

Product CodeDescriptionPack / Roll
ANTICON-60-R1.3Anticon 60mm — R1.3 — 1350mm wideRoll 15m²
ANTICON-75-R1.5Anticon 75mm — R1.5 — 1350mm wideRoll 12m²
ANTICON-100-R2.0Anticon 100mm — R2.0 — 1350mm wideRoll 10m²
ANTICON-120-R2.5Anticon 120mm — R2.5 — 1350mm wideRoll 8m²
ANTICON-150-R3.0Anticon 150mm — R3.0 — 1350mm wideRoll 6m²
ANTICON-200-R4.0Anticon 200mm — R4.0 — 1350mm wideRoll 5m²
ANTICON-60-R1.3-1800Anticon 60mm — R1.3 — 1800mm wideRoll 15m²
ANTICON-100-R2.0-1800Anticon 100mm — R2.0 — 1800mm wideRoll 10m²
ANTICON-150-R3.0-1800Anticon 150mm — R3.0 — 1800mm wideRoll 6m²

* R-values and dimensions are indicative. Contact us for current stock, NCC compliance advice and project pricing.

Foil-faced glasswool blanket for use in roof and wall systems where a reflective vapour barrier is required. The foil facing reflects radiant heat and acts as a vapour retarder, reducing condensation risk in metal building envelopes. Suitable for use with COLORBOND® roofing and wall cladding.

Product CodeDescriptionPack / Roll
FOIL-50-R1.1Foil blanket 50mm — R1.1 — 1350mm wideRoll 20m²
FOIL-75-R1.5Foil blanket 75mm — R1.5 — 1350mm wideRoll 15m²
FOIL-100-R2.0Foil blanket 100mm — R2.0 — 1350mm wideRoll 10m²
FOIL-120-R2.5Foil blanket 120mm — R2.5 — 1350mm wideRoll 8m²
FOIL-150-R3.0Foil blanket 150mm — R3.0 — 1350mm wideRoll 6m²
FOIL-50-R1.1-WALLFoil blanket 50mm — R1.1 — Wall grade — 1200mm wideRoll 20m²
FOIL-75-R1.5-WALLFoil blanket 75mm — R1.5 — Wall grade — 1200mm wideRoll 15m²
FOIL-100-R2.0-WALLFoil blanket 100mm — R2.0 — Wall grade — 1200mm wideRoll 10m²

* R-values and dimensions are indicative. Contact us for current stock, NCC compliance advice and project pricing.

Why Insulate Your Metal Roof?

Thermal Comfort
Reduce heat gain in summer and heat loss in winter, keeping your building comfortable year-round and cutting energy bills.
Rain Noise Reduction
Soundscreen and Anticon blankets dramatically reduce the drumming of rain on metal roofs — essential for residential and office buildings.
Condensation Control
Foil-faced blankets and sarking act as vapour retarders, preventing condensation from forming on the underside of metal sheeting.
NCC Compliance
Meet NCC Section J and BASIX energy efficiency requirements with the correct R-value products for your climate zone.

Technical Reference

Standards & R-Value Requirements

NCC Section J · AS/NZS 4859 · Climate zone R-value minimums · Application guidance

NCC 2022 — Section J

Energy efficiency for buildings

Section J of the National Construction Code sets minimum R-value requirements for roof and wall insulation in Class 2–9 buildings. Requirements vary by climate zone (1–8) and building class. Roof insulation R-values range from R1.4 (Zone 1 — tropical) to R6.3 (Zone 7 — alpine) for commercial buildings.

AS/NZS 4859.1:2018

Materials for the thermal insulation of buildings

Specifies test methods and performance requirements for thermal insulation materials including glasswool blankets (Anticon, Soundscreen), foil-faced products and PIR panels. R-values stated on product labels are tested and certified to this standard. Declared R-values are minimum values at 23°C mean temperature.

BASIX (NSW) / NatHERS

Residential energy efficiency compliance

NSW BASIX and NatHERS (National House Energy Rating Scheme) require residential buildings to achieve a minimum 6-star energy rating. Roof insulation is typically the single largest contributor to the thermal envelope score. Anticon R2.5–R4.0 under metal roofing is commonly specified to achieve 6-star compliance in temperate climates.

AS 1530.3:1999

Fire hazard properties — Spread of flame index

PIR (polyisocyanurate) insulated roof panels are tested to AS 1530.3 for spread of flame and smoke developed index. PIR panels with steel facings achieve a Spread of Flame Index of 0 and Smoke Developed Index ≤3, meeting the requirements of NCC Specification C1.10 for non-combustible construction in Class 5–9 buildings.

NCC 2022 Minimum Roof R-Values — Class 1 Residential (Indicative)

Climate ZoneDescriptionMin. Roof R-ValueRecommended Product
Zone 1High humidity summer, warm winter (Darwin, Cairns)R1.4Anticon 60mm R1.3 + foil
Zone 2Warm humid summer, mild winter (Brisbane, Townsville)R2.7Anticon 100mm R2.0 + foil
Zone 3Hot dry summer, cool winter (Perth, Adelaide)R2.7Anticon 100mm R2.0 + foil
Zone 4Mixed, moderate (Sydney, Melbourne)R3.2Anticon 120mm R2.5 + foil
Zone 5Warm temperate (parts of VIC, SA)R3.2Anticon 150mm R3.0 + foil
Zone 6Mild temperate (Canberra, Ballarat)R4.1Anticon 200mm R4.0 + foil
Zone 7Cool temperate (alpine areas)R5.1PIR panel or double-layer glasswool

* Indicative values only. Actual NCC requirements depend on building class, construction type and compliance pathway. Verify with your certifier or energy assessor.

Product Selection by Application

Residential Sheds

Anticon 75–100mm under COLORBOND® roofing; foil facing down; staple to purlins before sheeting

Commercial Buildings

Anticon 150–200mm for NCC Section J compliance; Soundscreen where rain noise is a concern

Industrial Warehouses

Anticon 60–100mm for condensation control; PIR panels for temperature-controlled storage

Cool Rooms / Freezers

PIR panels 75–150mm; steel-faced both sides; tongue-and-groove joints for airtight seal

Acoustic Applications

Soundscreen 100–200mm; significantly denser than Anticon; reduces rain noise by 8–12 dB

Wall Insulation

Foil-faced blanket 50–100mm between wall girts; foil facing inward as vapour retarder

Disclaimer: R-values stated are declared minimum values per AS/NZS 4859.1:2018 at 23°C mean temperature. Installed R-values may differ from product R-values depending on installation quality, compression and air gaps. NCC minimum R-value requirements are subject to change — always verify current requirements with your building certifier or energy assessor before specifying. Steel Source Australia supplies materials only and does not provide energy compliance advice.

Glasswool BlanketAnticon®Soundscreen®PIR Insulated PanelFoil-Faced InsulationRoof InsulationWall InsulationR1.3R1.5R2.0R2.5R3.0R3.5R4.0R5.0R6.375mm100mm150mmBlanket Width 900mmBlanket Width 1200mmNCC 2022 Section JAS/NZS 4859.1:2018BASIXNatHERSClimate Zone 1Climate Zone 2Climate Zone 3Climate Zone 4Climate Zone 5Climate Zone 6Climate Zone 7AS 1530.3Spread of Flame Index 0Metal Roofing InsulationShed InsulationCommercial InsulationIndustrial InsulationResidential InsulationBlueScope Anticon®Bradford Insulation

Need Help Choosing the Right Insulation?

Our team can help you select the correct R-value and product type for your climate zone, building class and budget. We supply insulation for residential sheds, commercial buildings and large industrial projects — with competitive bulk pricing and fast dispatch.