Steel Source Australia
HomeProductsRoof Safety Mesh
Roof Safety MeshAS/NZS 4389:2015Fall Protection10 Year Warranty

Roof Safety
Mesh

High-tensile galvanised roof safety mesh for fall protection during roof installation on domestic, commercial and industrial buildings. Constructed from 2 mm galvanised wire exceeding 450 MPa tensile strength, with a 150 mm × 300 mm rectangular grid. Complies with AS/NZS 4389:2015. Becomes a permanent fixture in the building once installed. Also supports foil underlays and synthetic sarking in enclosed roof spaces.

7
SKUs
Standard rolls + cut to length
3
Widths
1800 · 2250 · 2400 mm
≥ 500 MPa
Line Wire Tensile
Longitudinal wire minimum
AS/NZS 4389
Standard
Roof Safety Mesh 2015
Fall ProtectionDomestic RoofingCommercial RoofingIndustrial RoofingUnderlay SupportFoil Sarking SupportSynthetic Sarking SupportInsulation SupportSteel StructureTimber StructurePermanent Fixture
Important Limitations: Roof safety mesh is for use in enclosed buildings only. Not recommended for exposed structures (canopies, awnings), coastal or high-moisture environments. Must not be exposed to weather for more than 7 days — same-day coverage by roof cladding is recommended. No heavy roofing machinery to be placed on top. Refer to AS/NZS 4389:2015 and your state or territory building authority for installation requirements.

How It Works

Fall Protection System

01

Installed Between Rafters

Roof safety mesh is laid across and fixed to the rafters or purlins before roof cladding is installed. It spans the full bay width, providing a continuous fall-arrest surface below the cladding line.

02

Fixed with Mesh Fixing Strips

Pre-punched and folded 2 mm galvanised steel fixing strips are used to tension and secure the mesh to each rafter or purlin. Correct fixing is critical to the structural performance of the system.

03

Supports Underlay

Once fixed, the mesh supports foil underlays and synthetic sarking (e.g. Covertek 407, AIR-CELL Insuliner) in enclosed roof spaces. May also support insulation — check compatibility with the insulation manufacturer.

04

Permanent Fixture

Unlike temporary fall-arrest systems, roof safety mesh becomes a permanent fixture in the building once the roof cladding is installed over it. It remains in place for the life of the building.

Product Catalogue

Browse All SKUs

Click any section to expand and view full specifications. Add individual SKUs or entire sections to your enquiry.

E-E-A-T Technical Reference

Roof Safety Mesh Specifications

Wire specifications, dimensional definitions, scope of use, limitations and applicable standards for AS/NZS 4389:2015 compliant roof safety mesh.

Wire Specifications

PropertyLine Wire (Longitudinal)Cross Wire (Transverse)Standard Reference
Wire Diameter2.0 mm2.0 mmAS/NZS 4534:2006
Minimum Tensile Strength500 MPa450 MPaAS/NZS 4534:2006 WO2
Wire CoatingHot-dip galvanisedHot-dip galvanisedAS/NZS 4534:2006
Longitudinal Wire Spacing150 mm centresN/AAS/NZS 4389:2015
Transverse Wire SpacingN/A300 mm centresAS/NZS 4389:2015
Grid PatternRectangularRectangularAS/NZS 4389:2015

Primary Fall Protection

AS/NZS 4389:2015 compliant

Roof safety mesh is classified as a primary means of fall protection under AS/NZS 4389:2015. It is designed to arrest the fall of a worker through the roof plane during installation. It does not replace personal fall-arrest equipment (harnesses) where required by WHS regulations.

Permanent vs Temporary

Permanent fixture once cladding is installed

Unlike temporary edge protection or scaffolding, roof safety mesh becomes a permanent part of the building structure once the roof cladding is installed over it. It remains in place for the life of the building and does not need to be removed.

Underlay Support Function

Supports foil and synthetic sarking

In addition to fall protection, the mesh supports foil underlays (e.g. reflective foil laminates) and synthetic sarking (e.g. Covertek 407, AIR-CELL Insuliner) in enclosed roof spaces. It may also support insulation — compatibility must be confirmed with the insulation manufacturer.

Enclosed Buildings Only

Not for exposed structures

Roof safety mesh is only suitable for use in enclosed buildings. It must not be used in exposed structures such as canopies or awnings, as exposure to weather will compromise the durability of the galvanised coating and the structural performance of the mesh.

Weather Exposure Limit

Maximum 7 days unprotected

Once installed, the mesh must not be exposed to sunlight, dust, rain or other weather elements for more than 7 days. Same-day coverage by roof cladding is recommended. Prolonged exposure will degrade the galvanised coating and may compromise the fall-arrest performance.

10-Year Warranty

Subject to installation compliance

Roof safety mesh is warranted for 10 years, provided it is not damaged, is used only within the stated product limitations, is installed in accordance with the written installation instructions, and is compatible with the building structure materials used.

Scope of Use

Suitable Applications

  • —Primary fall protection during roof installation — domestic, commercial and industrial buildings
  • —Support of foil underlays in exposed roof spaces
  • —Support of synthetic underlays in enclosed roof spaces
  • —Support of insulation (check compatibility with insulation manufacturer)
  • —Steel structure and timber structure roofs

Not Suitable For

  • —Exposed structures — canopies, awnings, pergolas
  • —Coastal or seashore environments
  • —High internal moisture loading buildings
  • —Exposure to weather for more than 7 days without cladding coverage
  • —Use as a load-bearing platform for heavy roofing machinery or equipment

Applicable Standards

AS/NZS 4389:2015

Roof Safety Mesh

Primary Australian/New Zealand standard for roof safety mesh. Covers performance requirements, dimensional specifications, wire tensile strength, installation requirements and compliance testing for fall-protection mesh used in domestic, commercial and industrial roofing.

AS/NZS 4534:2006

Zinc and zinc/aluminium-alloy coatings on steel wire

Covers the zinc coating requirements for galvanised steel wire used in roof safety mesh. WO2 classification specifies minimum zinc coating mass for wire used in roof safety applications.

NCC (BCA) Volume 1 & 2

National Construction Code

The NCC requires fall protection for workers during construction. Roof safety mesh complying with AS/NZS 4389:2015 is an accepted solution for fall protection during roof installation under the NCC.

WHS Regulations 2017

Work Health and Safety Regulations

Commonwealth and state/territory WHS Regulations require fall protection for work at heights above 2 m. Roof safety mesh is one accepted means of fall protection. Personal fall-arrest equipment (harnesses) may also be required depending on the work method.

AS/NZS 1170.1:2002

Structural design actions — Permanent, imposed and other actions

Referenced for the structural design of roof safety mesh systems, including the imposed load requirements for fall-arrest applications.

AS 1650:1989

Hot-dipped galvanised coatings on ferrous articles

Referenced for the galvanised coating requirements on the mesh fixing strips and accessories used to install roof safety mesh.

Roof Safety MeshFall Protection MeshGalvanised Safety MeshAS/NZS 4389:2015Roof Underlay SupportHigh Tensile Wire MeshAusmeshRoof Mesh 1800mmRoof Mesh 2250mmRoof Mesh 2400mmWHS Fall ProtectionPermanent Roof MeshSarking Support MeshCommercial Roof Safety

Get a Quote

Need a Project Quote?

Cut-to-length orders available for all three widths. Add SKUs to your enquiry above or contact us with your project schedule and quantities.