Top-hat purlins, C-studs, U-track, equal angles and facade Z-sections from Millform — Australia's leading roll-formed steel manufacturer. G300 and G550 Z275 galvanised. All standard lengths in stock. Enquiry-based supply, no minimum order.
G550 (550 MPa yield) for top-hat purlins and battens where spanning capacity is critical. G300 (300 MPa yield) for studs, track, angles and accessories. Both grades comply with AS/NZS 1397:2021.
Z275 zinc coating (275 g/m² total both sides) is standard across the Millform range. Suitable for C1–C3 corrosivity environments. Z600 available for C4 marine environments on request.
0.55 BMT for non-structural battens and partitions. 0.75–1.00 BMT for structural purlins and load-bearing studs. 1.15–2.00 BMT for commercial framing, facade sub-frames and high-load applications.
Top-hat purlins: 6.0 m and 7.2 m. C-studs: 2.4 m, 2.7 m, 3.0 m and 3.6 m. U-track: 3.0 m and 6.0 m. Angles: 3.0 m and 6.0 m. Z-sections: 6.0 m. Custom cut lengths on request.
Millform top-hat sections (hat sections / omega sections) are roll-formed from G550 high-tensile Z275 galvanised steel strip. The trapezoidal profile delivers a high section modulus relative to weight, making them the preferred secondary structural member for spanning between primary rafters, columns and wall girts in steel-framed buildings. The 25 mm and 35 mm crown sections are used as roofing and wall battens to fix cladding to the primary frame. The 50 mm and 75 mm crown sections are used as structural purlins, wall girts and sub-frame members. All sections are pre-punched at 600 mm centres with 14 mm diameter service holes for ease of installation. Standard stock lengths are 6.0 m and 7.2 m.
Technical Note
G550 steel (550 MPa minimum yield strength) provides superior spanning capacity compared to G300 at equivalent BMT. For roofing battens, 0.55 BMT is standard. For structural purlins carrying sheeting loads, 0.75 BMT or 1.00 BMT is recommended. Always verify span against Millform published span tables and AS/NZS 4600:2018 for your specific load case and wind region.
| SKU | Description | Qty | Action | |
|---|---|---|---|---|
| TH25-055-6000 | Top-Hat 25 × 0.55 BMT G550 Z275 — 6.0 m length | 1 | ||
| TH25-055-7200 | Top-Hat 25 × 0.55 BMT G550 Z275 — 7.2 m length | 1 | ||
| TH25-075-6000 | Top-Hat 25 × 0.75 BMT G550 Z275 — 6.0 m length | 1 | ||
| TH35-055-6000 | Top-Hat 35 × 0.55 BMT G550 Z275 — 6.0 m length | 1 | ||
| TH35-055-7200 | Top-Hat 35 × 0.55 BMT G550 Z275 — 7.2 m length | 1 | ||
| TH35-075-6000 | Top-Hat 35 × 0.75 BMT G550 Z275 — 6.0 m length | 1 | ||
| TH35-075-7200 | Top-Hat 35 × 0.75 BMT G550 Z275 — 7.2 m length | 1 | ||
| TH35-100-6000 | Top-Hat 35 × 1.00 BMT G550 Z275 — 6.0 m length | 1 | ||
| TH50-055-6000 | Top-Hat 50 × 0.55 BMT G550 Z275 — 6.0 m length | 1 | ||
| TH50-055-7200 | Top-Hat 50 × 0.55 BMT G550 Z275 — 7.2 m length | 1 | ||
| TH50-075-6000 | Top-Hat 50 × 0.75 BMT G550 Z275 — 6.0 m length | 1 | ||
| TH50-075-7200 | Top-Hat 50 × 0.75 BMT G550 Z275 — 7.2 m length | 1 | ||
| TH50-100-6000 | Top-Hat 50 × 1.00 BMT G550 Z275 — 6.0 m length | 1 | ||
| TH50-100-7200 | Top-Hat 50 × 1.00 BMT G550 Z275 — 7.2 m length | 1 | ||
| TH50-120-6000 | Top-Hat 50 × 1.20 BMT G550 Z275 — 6.0 m length | 1 | ||
| TH75-075-6000 | Top-Hat 75 × 0.75 BMT G550 Z275 — 6.0 m length | 1 | ||
| TH75-075-7200 | Top-Hat 75 × 0.75 BMT G550 Z275 — 7.2 m length | 1 | ||
| TH75-100-6000 | Top-Hat 75 × 1.00 BMT G550 Z275 — 6.0 m length | 1 | ||
| TH75-100-7200 | Top-Hat 75 × 1.00 BMT G550 Z275 — 7.2 m length | 1 | ||
| TH75-120-6000 | Top-Hat 75 × 1.20 BMT G550 Z275 — 6.0 m length | 1 | ||
| TH75-120-7200 | Top-Hat 75 × 1.20 BMT G550 Z275 — 7.2 m length | 1 |
Millform C-studs are lipped C-sections used as vertical framing members in light steel wall frames. Manufactured from G300 Z275 galvanised steel to AS 3623:1993 (Domestic metal framing). Available in 64 mm, 76 mm, 92 mm and 150 mm web depths with 34 mm flanges (64–92 mm) or 45 mm flanges (150 mm) and a 10 mm return lip. The 0.55 BMT grade is specified for non-load-bearing partitions; 0.75 BMT for load-bearing domestic framing; 1.15 BMT for commercial and multi-storey applications. All sections are pre-punched with 32 × 16 mm oval service holes at 600 mm centres. Standard stock lengths are 2.4 m, 2.7 m, 3.0 m and 3.6 m.
Technical Note
AS 3623:1993 specifies minimum 0.55 BMT for non-load-bearing and 0.75 BMT for load-bearing domestic framing. Stud spacing is typically 450 mm or 600 mm centres depending on cladding type and wind load zone. For commercial and multi-storey applications, an engineer specification is required — consult Millform's design software (FrameCAD or equivalent) for load-bearing capacity tables.
| SKU | Description | Qty | Action | |
|---|---|---|---|---|
| CS64-055-2400 | C-Stud 64 × 34 × 10 × 0.55 BMT G300 Z275 — 2.4 m | 1 | ||
| CS64-055-2700 | C-Stud 64 × 34 × 10 × 0.55 BMT G300 Z275 — 2.7 m | 1 | ||
| CS64-055-3000 | C-Stud 64 × 34 × 10 × 0.55 BMT G300 Z275 — 3.0 m | 1 | ||
| CS64-055-3600 | C-Stud 64 × 34 × 10 × 0.55 BMT G300 Z275 — 3.6 m | 1 | ||
| CS64-075-2400 | C-Stud 64 × 34 × 10 × 0.75 BMT G300 Z275 — 2.4 m | 1 | ||
| CS64-075-2700 | C-Stud 64 × 34 × 10 × 0.75 BMT G300 Z275 — 2.7 m | 1 | ||
| CS64-075-3000 | C-Stud 64 × 34 × 10 × 0.75 BMT G300 Z275 — 3.0 m | 1 | ||
| CS64-115-2700 | C-Stud 64 × 34 × 10 × 1.15 BMT G300 Z275 — 2.7 m | 1 | ||
| CS64-115-3000 | C-Stud 64 × 34 × 10 × 1.15 BMT G300 Z275 — 3.0 m | 1 | ||
| CS76-055-2700 | C-Stud 76 × 34 × 10 × 0.55 BMT G300 Z275 — 2.7 m | 1 | ||
| CS76-055-3000 | C-Stud 76 × 34 × 10 × 0.55 BMT G300 Z275 — 3.0 m | 1 | ||
| CS76-075-2700 | C-Stud 76 × 34 × 10 × 0.75 BMT G300 Z275 — 2.7 m | 1 | ||
| CS76-075-3000 | C-Stud 76 × 34 × 10 × 0.75 BMT G300 Z275 — 3.0 m | 1 | ||
| CS76-115-2700 | C-Stud 76 × 34 × 10 × 1.15 BMT G300 Z275 — 2.7 m | 1 | ||
| CS92-055-2700 | C-Stud 92 × 34 × 10 × 0.55 BMT G300 Z275 — 2.7 m | 1 | ||
| CS92-055-3000 | C-Stud 92 × 34 × 10 × 0.55 BMT G300 Z275 — 3.0 m | 1 | ||
| CS92-055-3600 | C-Stud 92 × 34 × 10 × 0.55 BMT G300 Z275 — 3.6 m | 1 | ||
| CS92-075-2700 | C-Stud 92 × 34 × 10 × 0.75 BMT G300 Z275 — 2.7 m | 1 | ||
| CS92-075-3000 | C-Stud 92 × 34 × 10 × 0.75 BMT G300 Z275 — 3.0 m | 1 | ||
| CS92-075-3600 | C-Stud 92 × 34 × 10 × 0.75 BMT G300 Z275 — 3.6 m | 1 | ||
| CS92-115-2700 | C-Stud 92 × 34 × 10 × 1.15 BMT G300 Z275 — 2.7 m | 1 | ||
| CS92-115-3000 | C-Stud 92 × 34 × 10 × 1.15 BMT G300 Z275 — 3.0 m | 1 | ||
| CS150-075-2700 | C-Stud 150 × 45 × 10 × 0.75 BMT G300 Z275 — 2.7 m | 1 | ||
| CS150-075-3000 | C-Stud 150 × 45 × 10 × 0.75 BMT G300 Z275 — 3.0 m | 1 | ||
| CS150-075-3600 | C-Stud 150 × 45 × 10 × 0.75 BMT G300 Z275 — 3.6 m | 1 | ||
| CS150-115-2700 | C-Stud 150 × 45 × 10 × 1.15 BMT G300 Z275 — 2.7 m | 1 | ||
| CS150-115-3000 | C-Stud 150 × 45 × 10 × 1.15 BMT G300 Z275 — 3.0 m | 1 |
Millform U-track is the unlipped U-channel used as the top plate (head track) and bottom plate (sole track) in light steel wall frames. The C-stud slides inside the U-track to form the frame. Manufactured from G300 Z275 galvanised steel to AS 3623:1993. Available in 64 mm, 76 mm, 92 mm and 150 mm web depths to match the corresponding C-stud range. Flanges are 32 mm (64–92 mm webs) and 43 mm (150 mm web). Standard stock lengths are 3.0 m and 6.0 m.
Technical Note
U-track web depth must match the C-stud web depth used in the same wall frame. The track BMT should be equal to or greater than the stud BMT. For acoustic walls, a resilient bar or acoustic track may be required between the U-track and the substrate — consult the wall system specification.
| SKU | Description | Qty | Action | |
|---|---|---|---|---|
| UT64-055-3000 | U-Track 64 × 32 × 0.55 BMT G300 Z275 — 3.0 m | 1 | ||
| UT64-055-6000 | U-Track 64 × 32 × 0.55 BMT G300 Z275 — 6.0 m | 1 | ||
| UT64-075-3000 | U-Track 64 × 32 × 0.75 BMT G300 Z275 — 3.0 m | 1 | ||
| UT64-075-6000 | U-Track 64 × 32 × 0.75 BMT G300 Z275 — 6.0 m | 1 | ||
| UT64-115-3000 | U-Track 64 × 32 × 1.15 BMT G300 Z275 — 3.0 m | 1 | ||
| UT76-055-3000 | U-Track 76 × 32 × 0.55 BMT G300 Z275 — 3.0 m | 1 | ||
| UT76-055-6000 | U-Track 76 × 32 × 0.55 BMT G300 Z275 — 6.0 m | 1 | ||
| UT76-075-3000 | U-Track 76 × 32 × 0.75 BMT G300 Z275 — 3.0 m | 1 | ||
| UT76-075-6000 | U-Track 76 × 32 × 0.75 BMT G300 Z275 — 6.0 m | 1 | ||
| UT92-055-3000 | U-Track 92 × 32 × 0.55 BMT G300 Z275 — 3.0 m | 1 | ||
| UT92-055-6000 | U-Track 92 × 32 × 0.55 BMT G300 Z275 — 6.0 m | 1 | ||
| UT92-075-3000 | U-Track 92 × 32 × 0.75 BMT G300 Z275 — 3.0 m | 1 | ||
| UT92-075-6000 | U-Track 92 × 32 × 0.75 BMT G300 Z275 — 6.0 m | 1 | ||
| UT92-115-3000 | U-Track 92 × 32 × 1.15 BMT G300 Z275 — 3.0 m | 1 | ||
| UT92-115-6000 | U-Track 92 × 32 × 1.15 BMT G300 Z275 — 6.0 m | 1 | ||
| UT150-075-3000 | U-Track 150 × 43 × 0.75 BMT G300 Z275 — 3.0 m | 1 | ||
| UT150-075-6000 | U-Track 150 × 43 × 0.75 BMT G300 Z275 — 6.0 m | 1 | ||
| UT150-115-3000 | U-Track 150 × 43 × 1.15 BMT G300 Z275 — 3.0 m | 1 | ||
| UT150-115-6000 | U-Track 150 × 43 × 1.15 BMT G300 Z275 — 6.0 m | 1 |
Millform roll-formed equal angles are manufactured from G300 Z275 galvanised steel. Available in 25×25 mm, 30×30 mm, 40×40 mm and 50×50 mm leg sizes with BMT options of 0.75 mm, 1.00 mm and 1.20 mm. Used extensively in light steel framing for corner reinforcement, lintel support, bracing connections, edge trim and cladding termination details. Standard stock lengths are 3.0 m and 6.0 m. Stainless steel (Grade 304 and Grade 316) angles are available on request for coastal and food-grade applications.
Technical Note
For structural bracing applications, minimum 1.00 BMT is recommended. For non-structural edge trim and cladding termination, 0.75 BMT is standard. In marine environments (within 1 km of coastline), specify Grade 316 stainless or hot-dip galvanised angles to AS/NZS 4680 to prevent corrosion.
| SKU | Description | Qty | Action | |
|---|---|---|---|---|
| EA25-075-3000 | Equal Angle 25 × 25 × 0.75 BMT G300 Z275 — 3.0 m | 1 | ||
| EA25-075-6000 | Equal Angle 25 × 25 × 0.75 BMT G300 Z275 — 6.0 m | 1 | ||
| EA25-100-3000 | Equal Angle 25 × 25 × 1.00 BMT G300 Z275 — 3.0 m | 1 | ||
| EA30-075-3000 | Equal Angle 30 × 30 × 0.75 BMT G300 Z275 — 3.0 m | 1 | ||
| EA30-075-6000 | Equal Angle 30 × 30 × 0.75 BMT G300 Z275 — 6.0 m | 1 | ||
| EA30-100-3000 | Equal Angle 30 × 30 × 1.00 BMT G300 Z275 — 3.0 m | 1 | ||
| EA30-100-6000 | Equal Angle 30 × 30 × 1.00 BMT G300 Z275 — 6.0 m | 1 | ||
| EA40-075-3000 | Equal Angle 40 × 40 × 0.75 BMT G300 Z275 — 3.0 m | 1 | ||
| EA40-075-6000 | Equal Angle 40 × 40 × 0.75 BMT G300 Z275 — 6.0 m | 1 | ||
| EA40-100-3000 | Equal Angle 40 × 40 × 1.00 BMT G300 Z275 — 3.0 m | 1 | ||
| EA40-100-6000 | Equal Angle 40 × 40 × 1.00 BMT G300 Z275 — 6.0 m | 1 | ||
| EA40-120-3000 | Equal Angle 40 × 40 × 1.20 BMT G300 Z275 — 3.0 m | 1 | ||
| EA40-120-6000 | Equal Angle 40 × 40 × 1.20 BMT G300 Z275 — 6.0 m | 1 | ||
| EA50-100-3000 | Equal Angle 50 × 50 × 1.00 BMT G300 Z275 — 3.0 m | 1 | ||
| EA50-100-6000 | Equal Angle 50 × 50 × 1.00 BMT G300 Z275 — 6.0 m | 1 | ||
| EA50-120-3000 | Equal Angle 50 × 50 × 1.20 BMT G300 Z275 — 3.0 m | 1 | ||
| EA50-120-6000 | Equal Angle 50 × 50 × 1.20 BMT G300 Z275 — 6.0 m | 1 | ||
| EA40-100-SS304-3000 | Equal Angle 40 × 40 × 1.00 BMT Grade 304 Stainless — 3.0 m | 1 | ||
| EA40-100-SS316-3000 | Equal Angle 40 × 40 × 1.00 BMT Grade 316 Stainless — 3.0 m | 1 | ||
| EA50-100-SS316-3000 | Equal Angle 50 × 50 × 1.00 BMT Grade 316 Stainless — 3.0 m | 1 |
Millform Z-sections are roll-formed from G300 Z275 galvanised steel and used as horizontal sub-frame members in rainscreen facade systems, spanning between vertical wall brackets or the primary structure. The asymmetric Z profile allows sections to overlap and nest at splices for continuous runs without butt joints. Available in 100 mm, 150 mm, 200 mm and 250 mm web depths with BMT options from 1.00 mm to 2.00 mm. Suitable for fibre cement, compressed fibre cement, aluminium composite panel (ACP), metal cassette and terracotta rainscreen facades. Standard stock length is 6.0 m.
Technical Note
Facade sub-frame design must account for wind pressure (positive and negative) per AS/NZS 1170.2, thermal movement of the cladding panel, and the corrosivity classification of the environment per AS/NZS 2312.2. In C4 (marine) environments, Z600 coating or hot-dip galvanised sections are recommended. Thermal break pads between the Z-section and wall bracket are required for NCC Section J compliance in climate zones 6–8.
| SKU | Description | Qty | Action | |
|---|---|---|---|---|
| ZS100-100-6000 | Z-Section 100 × 1.00 BMT G300 Z275 — 6.0 m | 1 | ||
| ZS100-120-6000 | Z-Section 100 × 1.20 BMT G300 Z275 — 6.0 m | 1 | ||
| ZS100-150-6000 | Z-Section 100 × 1.50 BMT G300 Z275 — 6.0 m | 1 | ||
| ZS150-100-6000 | Z-Section 150 × 1.00 BMT G300 Z275 — 6.0 m | 1 | ||
| ZS150-120-6000 | Z-Section 150 × 1.20 BMT G300 Z275 — 6.0 m | 1 | ||
| ZS150-150-6000 | Z-Section 150 × 1.50 BMT G300 Z275 — 6.0 m | 1 | ||
| ZS150-200-6000 | Z-Section 150 × 2.00 BMT G300 Z275 — 6.0 m | 1 | ||
| ZS200-120-6000 | Z-Section 200 × 1.20 BMT G300 Z275 — 6.0 m | 1 | ||
| ZS200-150-6000 | Z-Section 200 × 1.50 BMT G300 Z275 — 6.0 m | 1 | ||
| ZS200-200-6000 | Z-Section 200 × 2.00 BMT G300 Z275 — 6.0 m | 1 | ||
| ZS250-150-6000 | Z-Section 250 × 1.50 BMT G300 Z275 — 6.0 m | 1 | ||
| ZS250-200-6000 | Z-Section 250 × 2.00 BMT G300 Z275 — 6.0 m | 1 |
Light steel framing requires a range of accessories to complete the structural system. Bridging channels prevent stud rotation under lateral load and must be installed at maximum 1.2 m vertical centres. Flat strap bracing provides diagonal tension bracing in wall frames. Hold-down brackets resist uplift at the base of studs. Stud-to-track connectors (STC clips) provide a positive mechanical connection between stud and track without the need for screws through the track flange. All accessories are manufactured from G300 Z275 galvanised steel and are compatible with the Millform 64 mm, 76 mm, 92 mm and 150 mm stud/track system.
Technical Note
Bridging channels must be installed at maximum 1.2 m vertical centres to prevent stud rotation under lateral load per AS/NZS 4600:2018. Flat strap bracing must be tensioned and fixed at each end to a structural element. Hold-down brackets must be designed for the specific uplift load — consult your structural engineer for sizing and anchor bolt specification.
| SKU | Description | Qty | Action | |
|---|---|---|---|---|
| BRIDGE-64-1200 | Bridging channel — suits 64 mm studs — 1.2 m cut length — Z275 | 1 | ||
| BRIDGE-92-1200 | Bridging channel — suits 92 mm studs — 1.2 m cut length — Z275 | 1 | ||
| BRIDGE-150-1200 | Bridging channel — suits 150 mm studs — 1.2 m cut length — Z275 | 1 | ||
| STRAP-30-075-30M | Flat strap bracing 30 × 0.75 BMT Z275 — 30 m coil | 1 | ||
| STRAP-30-100-30M | Flat strap bracing 30 × 1.00 BMT Z275 — 30 m coil | 1 | ||
| STRAP-CLIP-30 | Strap bracing clip — suits 30 mm strap — Z275 | 1 | ||
| HD-64-Z275 | Hold-down bracket — suits 64 mm stud — Z275 | 1 | ||
| HD-92-Z275 | Hold-down bracket — suits 92 mm stud — Z275 | 1 | ||
| HD-150-Z275 | Hold-down bracket — suits 150 mm stud — Z275 | 1 | ||
| STC-64-92 | Stud-to-track connector (STC clip) — suits 64–92 mm — Z275 | 1 | ||
| STC-150 | Stud-to-track connector (STC clip) — suits 150 mm — Z275 | 1 | ||
| LINTEL-64 | Lintel bracket — suits 64 mm stud — Z275 | 1 | ||
| LINTEL-92 | Lintel bracket — suits 92 mm stud — Z275 | 1 | ||
| NOGG-64-055 | Nogging C-section 64 mm × 0.55 BMT — 1.2 m cut length | 1 | ||
| NOGG-92-055 | Nogging C-section 92 mm × 0.55 BMT — 1.2 m cut length | 1 |
Applicable Standards
AS/NZS 4600:2018
Cold-Formed Steel Structures
Primary design standard for all roll-formed sections used in structural applications. Governs section capacity, connection design and stability.
AS/NZS 1397:2021
Metallic Coated Steel Sheet & Strip
Specifies Z275 zinc coating mass and mechanical properties for G300 and G550 steel strip used in Millform sections.
AS 3623:1993
Domestic Metal Framing
Governs C-stud, U-track and nogging dimensions, BMT minimums and connection requirements for residential light steel framing.
AS/NZS 4284:2008
Testing of Building Facades
Performance testing for facade sub-frame systems under wind pressure, water penetration and structural load.
AS/NZS 2312.2:2014
Corrosivity Classification
Determines appropriate zinc coating grade (Z275 vs Z600 vs hot-dip galvanised) for the project's exposure environment.
NCC 2022 Vol. One
National Construction Code
Section B (Structure) and Section J (Energy Efficiency) requirements for steel framing, including thermal bridging through sub-frame systems.
Add items to your enquiry cart and submit — or call our team for project pricing on steel framing systems.