Steel Source Australia
Structural133 SKUs across 7 categoriesAS/NZS 4600:2018 · G450 / G550

Rollformed Structural Members

C-purlins (C100–C250), Z-purlins (Z150–Z250), bridging channel, sag rods, purlin cleats, eave struts, wall girts and structural fasteners. G450/G550 Z350 galvanised steel. Standard lengths 6.0 m, 7.2 m, 9.0 m and 12.0 m. Enquiry-based supply.

G450 & G550 High-Tensile
Z350 Zinc Coating
1.5–3.0 BMT Range
6.0m, 7.2m, 9.0m, 12.0m

Quick Reference — Purlin Sizes

C100

100×65×20mm

BMT1.5, 2.0, 2.5 BMT
GradeG450 Z350
Lengths6.0m
UseLight purlins, short spans

C150 / Z150

150×65×20mm

BMT1.5, 1.9, 2.4, 3.0 BMT
GradeG450/G550 Z350
Lengths6.0m, 7.2m, 9.0m
UseStandard purlin — most common

C200 / Z200

200×75×25mm

BMT1.5, 1.9, 2.4, 3.0 BMT
GradeG450/G550 Z350
Lengths6.0m, 7.2m, 9.0m, 12.0m
UseMedium-span purlins & girts

C230 / Z230

230×75×25mm

BMT1.9, 2.4, 3.0 BMT
GradeG450/G550 Z350
Lengths6.0m, 7.2m, 9.0m
UseLong-span purlins

C250 / Z250

250×75×25mm

BMT2.4, 3.0 BMT
GradeG450/G550 Z350
Lengths6.0m, 7.2m, 9.0m
UseHeavy-load, long-span purlins

Z-Purlins

Same as C range

BMT1.5–3.0 BMT
GradeG450/G550 Z350
Lengths6.0m, 7.2m, 9.0m
UseLapped continuous systems — LH & RH

C-purlins (lipped channel sections) are the primary rollformed structural member for roof purlins and wall girts in steel-framed industrial, commercial and agricultural buildings. Manufactured from G450 or G550 high-tensile Z350 galvanised steel, Millform C-purlins are available in web depths of 100 mm, 150 mm, 200 mm, 230 mm and 250 mm, with flange widths of 65 mm and lips of 20 mm. BMT options range from 1.5 mm to 3.0 mm. Standard lengths are 6.0 m, 7.2 m, 8.0 m, 9.0 m and 12.0 m. All sections are pre-punched with 18 mm diameter holes at 200 mm centres in the web for bridging rod and services.

Technical Note

C-purlin span capacity is governed by AS/NZS 4600:2018. For continuous spans (lapped at supports), capacity increases by approximately 50% over simple span. Minimum lap length is 10% of span or 300 mm, whichever is greater. Bridging is required at mid-span for spans over 6.0 m. Verify span tables for your specific load case, purlin spacing and wind region.

SKUDescriptionQTYLength (mm)
CP100-15-6.0C-purlin C100 — 100×65×20mm — 1.5 BMT G450 Z350 — 6.0m
1
—
CP100-20-6.0C-purlin C100 — 100×65×20mm — 2.0 BMT G450 Z350 — 6.0m
1
—
CP100-25-6.0C-purlin C100 — 100×65×20mm — 2.5 BMT G450 Z350 — 6.0m
1
—
CP150-15-6.0C-purlin C150 — 150×65×20mm — 1.5 BMT G450 Z350 — 6.0m
1
—
CP150-19-6.0C-purlin C150 — 150×65×20mm — 1.9 BMT G450 Z350 — 6.0m
1
—
CP150-24-6.0C-purlin C150 — 150×65×20mm — 2.4 BMT G450 Z350 — 6.0m
1
—
CP150-30-6.0C-purlin C150 — 150×65×20mm — 3.0 BMT G550 Z350 — 6.0m
1
—
CP150-15-7.2C-purlin C150 — 150×65×20mm — 1.5 BMT G450 Z350 — 7.2m
1
—
CP150-19-7.2C-purlin C150 — 150×65×20mm — 1.9 BMT G450 Z350 — 7.2m
1
—
CP150-24-7.2C-purlin C150 — 150×65×20mm — 2.4 BMT G450 Z350 — 7.2m
1
—
CP150-19-9.0C-purlin C150 — 150×65×20mm — 1.9 BMT G450 Z350 — 9.0m
1
—
CP150-24-9.0C-purlin C150 — 150×65×20mm — 2.4 BMT G450 Z350 — 9.0m
1
—
CP200-15-6.0C-purlin C200 — 200×75×25mm — 1.5 BMT G450 Z350 — 6.0m
1
—
CP200-19-6.0C-purlin C200 — 200×75×25mm — 1.9 BMT G450 Z350 — 6.0m
1
—
CP200-24-6.0C-purlin C200 — 200×75×25mm — 2.4 BMT G450 Z350 — 6.0m
1
—
CP200-30-6.0C-purlin C200 — 200×75×25mm — 3.0 BMT G550 Z350 — 6.0m
1
—
CP200-15-7.2C-purlin C200 — 200×75×25mm — 1.5 BMT G450 Z350 — 7.2m
1
—
CP200-19-7.2C-purlin C200 — 200×75×25mm — 1.9 BMT G450 Z350 — 7.2m
1
—
CP200-24-7.2C-purlin C200 — 200×75×25mm — 2.4 BMT G450 Z350 — 7.2m
1
—
CP200-19-9.0C-purlin C200 — 200×75×25mm — 1.9 BMT G450 Z350 — 9.0m
1
—
CP200-24-9.0C-purlin C200 — 200×75×25mm — 2.4 BMT G450 Z350 — 9.0m
1
—
CP200-24-12.0C-purlin C200 — 200×75×25mm — 2.4 BMT G450 Z350 — 12.0m
1
—
CP230-19-6.0C-purlin C230 — 230×75×25mm — 1.9 BMT G450 Z350 — 6.0m
1
—
CP230-24-6.0C-purlin C230 — 230×75×25mm — 2.4 BMT G450 Z350 — 6.0m
1
—
CP230-30-6.0C-purlin C230 — 230×75×25mm — 3.0 BMT G550 Z350 — 6.0m
1
—
CP230-19-7.2C-purlin C230 — 230×75×25mm — 1.9 BMT G450 Z350 — 7.2m
1
—
CP230-24-7.2C-purlin C230 — 230×75×25mm — 2.4 BMT G450 Z350 — 7.2m
1
—
CP230-24-9.0C-purlin C230 — 230×75×25mm — 2.4 BMT G450 Z350 — 9.0m
1
—
CP250-24-6.0C-purlin C250 — 250×75×25mm — 2.4 BMT G450 Z350 — 6.0m
1
—
CP250-30-6.0C-purlin C250 — 250×75×25mm — 3.0 BMT G550 Z350 — 6.0m
1
—
CP250-24-7.2C-purlin C250 — 250×75×25mm — 2.4 BMT G450 Z350 — 7.2m
1
—
CP250-30-7.2C-purlin C250 — 250×75×25mm — 3.0 BMT G550 Z350 — 7.2m
1
—
CP250-24-9.0C-purlin C250 — 250×75×25mm — 2.4 BMT G450 Z350 — 9.0m
1
—

Z-purlins (zed sections) are used in overlapping continuous purlin systems where the opposing flanges allow adjacent purlins to nest and overlap at supports, providing a highly efficient continuous beam action. Millform Z-purlins are available in web depths of 150 mm, 200 mm, 230 mm and 250 mm, with 65 mm or 75 mm flanges and 20–25 mm lips. BMT options from 1.5 mm to 3.0 mm. Standard lengths are 6.0 m, 7.2 m, 8.0 m, 9.0 m and 12.0 m. Z-purlins are supplied in left-hand (LH) and right-hand (RH) orientations for lapping — specify orientation when ordering.

Technical Note

Z-purlin lapped systems provide 30–50% greater span capacity than simple-span C-purlins of the same section. Minimum lap length per AS/NZS 4600:2018 is 10% of span or 300 mm. Laps must be bolted with a minimum of two M12 bolts per lap. Bridging is required at mid-span and at 1/3 points for spans over 9.0 m.

SKUDescriptionQTYLength (mm)
ZP150-15-6.0-LHZ-purlin Z150 — 150×65×20mm — 1.5 BMT G450 Z350 — 6.0m — LH
1
—
ZP150-15-6.0-RHZ-purlin Z150 — 150×65×20mm — 1.5 BMT G450 Z350 — 6.0m — RH
1
—
ZP150-19-6.0-LHZ-purlin Z150 — 150×65×20mm — 1.9 BMT G450 Z350 — 6.0m — LH
1
—
ZP150-19-6.0-RHZ-purlin Z150 — 150×65×20mm — 1.9 BMT G450 Z350 — 6.0m — RH
1
—
ZP150-24-6.0-LHZ-purlin Z150 — 150×65×20mm — 2.4 BMT G450 Z350 — 6.0m — LH
1
—
ZP150-24-6.0-RHZ-purlin Z150 — 150×65×20mm — 2.4 BMT G450 Z350 — 6.0m — RH
1
—
ZP150-19-7.2-LHZ-purlin Z150 — 150×65×20mm — 1.9 BMT G450 Z350 — 7.2m — LH
1
—
ZP150-19-7.2-RHZ-purlin Z150 — 150×65×20mm — 1.9 BMT G450 Z350 — 7.2m — RH
1
—
ZP200-15-6.0-LHZ-purlin Z200 — 200×75×25mm — 1.5 BMT G450 Z350 — 6.0m — LH
1
—
ZP200-15-6.0-RHZ-purlin Z200 — 200×75×25mm — 1.5 BMT G450 Z350 — 6.0m — RH
1
—
ZP200-19-6.0-LHZ-purlin Z200 — 200×75×25mm — 1.9 BMT G450 Z350 — 6.0m — LH
1
—
ZP200-19-6.0-RHZ-purlin Z200 — 200×75×25mm — 1.9 BMT G450 Z350 — 6.0m — RH
1
—
ZP200-24-6.0-LHZ-purlin Z200 — 200×75×25mm — 2.4 BMT G450 Z350 — 6.0m — LH
1
—
ZP200-24-6.0-RHZ-purlin Z200 — 200×75×25mm — 2.4 BMT G450 Z350 — 6.0m — RH
1
—
ZP200-30-6.0-LHZ-purlin Z200 — 200×75×25mm — 3.0 BMT G550 Z350 — 6.0m — LH
1
—
ZP200-30-6.0-RHZ-purlin Z200 — 200×75×25mm — 3.0 BMT G550 Z350 — 6.0m — RH
1
—
ZP200-19-7.2-LHZ-purlin Z200 — 200×75×25mm — 1.9 BMT G450 Z350 — 7.2m — LH
1
—
ZP200-19-7.2-RHZ-purlin Z200 — 200×75×25mm — 1.9 BMT G450 Z350 — 7.2m — RH
1
—
ZP200-24-7.2-LHZ-purlin Z200 — 200×75×25mm — 2.4 BMT G450 Z350 — 7.2m — LH
1
—
ZP200-24-7.2-RHZ-purlin Z200 — 200×75×25mm — 2.4 BMT G450 Z350 — 7.2m — RH
1
—
ZP200-24-9.0-LHZ-purlin Z200 — 200×75×25mm — 2.4 BMT G450 Z350 — 9.0m — LH
1
—
ZP200-24-9.0-RHZ-purlin Z200 — 200×75×25mm — 2.4 BMT G450 Z350 — 9.0m — RH
1
—
ZP230-24-6.0-LHZ-purlin Z230 — 230×75×25mm — 2.4 BMT G450 Z350 — 6.0m — LH
1
—
ZP230-24-6.0-RHZ-purlin Z230 — 230×75×25mm — 2.4 BMT G450 Z350 — 6.0m — RH
1
—
ZP230-30-6.0-LHZ-purlin Z230 — 230×75×25mm — 3.0 BMT G550 Z350 — 6.0m — LH
1
—
ZP230-30-6.0-RHZ-purlin Z230 — 230×75×25mm — 3.0 BMT G550 Z350 — 6.0m — RH
1
—
ZP230-24-7.2-LHZ-purlin Z230 — 230×75×25mm — 2.4 BMT G450 Z350 — 7.2m — LH
1
—
ZP230-24-7.2-RHZ-purlin Z230 — 230×75×25mm — 2.4 BMT G450 Z350 — 7.2m — RH
1
—
ZP250-24-6.0-LHZ-purlin Z250 — 250×75×25mm — 2.4 BMT G450 Z350 — 6.0m — LH
1
—
ZP250-24-6.0-RHZ-purlin Z250 — 250×75×25mm — 2.4 BMT G450 Z350 — 6.0m — RH
1
—
ZP250-30-6.0-LHZ-purlin Z250 — 250×75×25mm — 3.0 BMT G550 Z350 — 6.0m — LH
1
—
ZP250-30-6.0-RHZ-purlin Z250 — 250×75×25mm — 3.0 BMT G550 Z350 — 6.0m — RH
1
—
ZP250-24-7.2-LHZ-purlin Z250 — 250×75×25mm — 2.4 BMT G450 Z350 — 7.2m — LH
1
—
ZP250-24-7.2-RHZ-purlin Z250 — 250×75×25mm — 2.4 BMT G450 Z350 — 7.2m — RH
1
—
ZP250-30-7.2-LHZ-purlin Z250 — 250×75×25mm — 3.0 BMT G550 Z350 — 7.2m — LH
1
—
ZP250-30-7.2-RHZ-purlin Z250 — 250×75×25mm — 3.0 BMT G550 Z350 — 7.2m — RH
1
—

Bridging provides lateral restraint to C and Z purlins, preventing lateral-torsional buckling under load. Millform supplies three bridging systems: (1) Bridging channel — a roll-formed C-section clipped to the purlin web; (2) Sag rods — 12 mm or 16 mm diameter round bar threaded at each end, tensioned between purlins; (3) Anti-sag bars — flat bar or angle welded between purlins at mid-span. Bridging must be installed at mid-span for spans over 6.0 m, and at third-points for spans over 9.0 m, per AS/NZS 4600:2018.

Technical Note

Bridging must be connected to a fixed point (rafter, column or end wall) to be effective. Sag rods must be tensioned — slack sag rods provide no lateral restraint. For Z-purlin lapped systems, bridging is required at the lap point as well as mid-span.

SKUDescriptionQTYLength (mm)
BC-C150-6.0Bridging channel — suits C/Z150 purlins — G300 Z275 — 6.0m
1
—
BC-C200-6.0Bridging channel — suits C/Z200 purlins — G300 Z275 — 6.0m
1
—
BC-C230-6.0Bridging channel — suits C/Z230 purlins — G300 Z275 — 6.0m
1
—
BC-C250-6.0Bridging channel — suits C/Z250 purlins — G300 Z275 — 6.0m
1
—
BC-CLIP-C150Bridging clip — suits C/Z150 purlin web — Z275 galvanised
1
—
BC-CLIP-C200Bridging clip — suits C/Z200 purlin web — Z275 galvanised
1
—
BC-CLIP-C230Bridging clip — suits C/Z230 purlin web — Z275 galvanised
1
—
BC-CLIP-C250Bridging clip — suits C/Z250 purlin web — Z275 galvanised
1
—
SR-12-6.0Sag rod — 12mm dia. threaded rod — galvanised — 6.0m length
1
—
SR-16-6.0Sag rod — 16mm dia. threaded rod — galvanised — 6.0m length
1
—
SR-NUT-12Sag rod nut & washer set — suits 12mm rod — galvanised
1
—
SR-NUT-16Sag rod nut & washer set — suits 16mm rod — galvanised
1
—
ASB-40-6.0Anti-sag bar — 40×5mm flat bar — G300 Z275 — 6.0m
1
—
ASB-50-6.0Anti-sag bar — 50×5mm flat bar — G300 Z275 — 6.0m
1
—

Purlin cleats connect C and Z purlins to the top flange of primary rafters. Millform supplies a comprehensive range of cleats for C-purlin and Z-purlin systems, including standard purlin cleats (welded or bolted to rafter), apex cleats (for ridge connections), eave cleats (for eave purlin connections) and adjustable rafter brackets (for variable rafter pitch). All cleats are manufactured from G300 Z275 galvanised steel and are pre-drilled for M12 bolts.

Technical Note

Cleat selection depends on purlin depth, rafter flange width and the design uplift load. For high-wind regions (C and D), use heavy-duty cleats with a minimum of four M12 bolts per connection. Apex cleats must be designed to transfer the horizontal thrust from opposing rafters.

SKUDescriptionQTYLength (mm)
PC-C150-STDPurlin cleat — suits C/Z150 — standard — G300 Z275 galvanised
1
—
PC-C200-STDPurlin cleat — suits C/Z200 — standard — G300 Z275 galvanised
1
—
PC-C230-STDPurlin cleat — suits C/Z230 — standard — G300 Z275 galvanised
1
—
PC-C250-STDPurlin cleat — suits C/Z250 — standard — G300 Z275 galvanised
1
—
PC-C150-HDPurlin cleat — suits C/Z150 — heavy duty — G300 Z275 galvanised
1
—
PC-C200-HDPurlin cleat — suits C/Z200 — heavy duty — G300 Z275 galvanised
1
—
PC-C230-HDPurlin cleat — suits C/Z230 — heavy duty — G300 Z275 galvanised
1
—
PC-C250-HDPurlin cleat — suits C/Z250 — heavy duty — G300 Z275 galvanised
1
—
AC-C150Apex cleat — suits C/Z150 — G300 Z275 galvanised
1
—
AC-C200Apex cleat — suits C/Z200 — G300 Z275 galvanised
1
—
EC-C150Eave cleat — suits C/Z150 — G300 Z275 galvanised
1
—
EC-C200Eave cleat — suits C/Z200 — G300 Z275 galvanised
1
—
ARB-C150Adjustable rafter bracket — suits C/Z150 — G300 Z275 galvanised
1
—
ARB-C200Adjustable rafter bracket — suits C/Z200 — G300 Z275 galvanised
1
—

Wall girts are horizontal C or Z sections spanning between columns to support wall cladding. They carry wind load (suction and pressure) and the self-weight of the cladding. The same C-purlin and Z-purlin section range is used for wall girts — selection depends on column spacing, cladding weight and wind load zone. Millform wall girts are supplied in the same lengths and BMT options as the purlin range. Girt-to-column connections use standard purlin cleats or welded plate connections.

Technical Note

Wall girt design must consider both inward (pressure) and outward (suction) wind loads per AS/NZS 1170.2. In high-wind regions, suction loads often govern girt selection. Bridging is required for girt spans over 6.0 m. For cladding with a high self-weight (e.g. masonry veneer), verify girt deflection limits per NCC 2022.

SKUDescriptionQTYLength (mm)
WG-C150-15-6.0Wall girt C150 — 150×65×20mm — 1.5 BMT G450 Z350 — 6.0m
1
—
WG-C150-19-6.0Wall girt C150 — 150×65×20mm — 1.9 BMT G450 Z350 — 6.0m
1
—
WG-C150-24-6.0Wall girt C150 — 150×65×20mm — 2.4 BMT G450 Z350 — 6.0m
1
—
WG-C200-15-6.0Wall girt C200 — 200×75×25mm — 1.5 BMT G450 Z350 — 6.0m
1
—
WG-C200-19-6.0Wall girt C200 — 200×75×25mm — 1.9 BMT G450 Z350 — 6.0m
1
—
WG-C200-24-6.0Wall girt C200 — 200×75×25mm — 2.4 BMT G450 Z350 — 6.0m
1
—
WG-C200-19-7.2Wall girt C200 — 200×75×25mm — 1.9 BMT G450 Z350 — 7.2m
1
—
WG-C200-24-7.2Wall girt C200 — 200×75×25mm — 2.4 BMT G450 Z350 — 7.2m
1
—
WG-Z150-19-6.0-LHWall girt Z150 — 150×65×20mm — 1.9 BMT G450 Z350 — 6.0m — LH
1
—
WG-Z150-19-6.0-RHWall girt Z150 — 150×65×20mm — 1.9 BMT G450 Z350 — 6.0m — RH
1
—
WG-Z200-19-6.0-LHWall girt Z200 — 200×75×25mm — 1.9 BMT G450 Z350 — 6.0m — LH
1
—
WG-Z200-19-6.0-RHWall girt Z200 — 200×75×25mm — 1.9 BMT G450 Z350 — 6.0m — RH
1
—
WG-Z200-24-6.0-LHWall girt Z200 — 200×75×25mm — 2.4 BMT G450 Z350 — 6.0m — LH
1
—
WG-Z200-24-6.0-RHWall girt Z200 — 200×75×25mm — 2.4 BMT G450 Z350 — 6.0m — RH
1
—

Eave struts serve the dual function of eave purlin (supporting roof sheeting at the eave) and top wall girt (supporting wall cladding at the eave). They are typically a deeper C or Z section than the standard purlin to accommodate the combined loading. Millform eave struts are available in C200, C230 and C250 sections in 2.4 BMT and 3.0 BMT. Ridge caps are roll-formed C-sections used at the apex to close the ridge and support the ridge capping flashing.

Technical Note

Eave struts must be designed for the combined roof and wall wind loads. In cyclonic regions (C and D), eave struts are typically the most heavily loaded member in the purlin system. Verify eave strut capacity with your structural engineer for wind regions C and D.

SKUDescriptionQTYLength (mm)
ES-C200-24-6.0Eave strut C200 — 200×75×25mm — 2.4 BMT G450 Z350 — 6.0m
1
—
ES-C200-30-6.0Eave strut C200 — 200×75×25mm — 3.0 BMT G550 Z350 — 6.0m
1
—
ES-C230-24-6.0Eave strut C230 — 230×75×25mm — 2.4 BMT G450 Z350 — 6.0m
1
—
ES-C230-30-6.0Eave strut C230 — 230×75×25mm — 3.0 BMT G550 Z350 — 6.0m
1
—
ES-C250-24-6.0Eave strut C250 — 250×75×25mm — 2.4 BMT G450 Z350 — 6.0m
1
—
ES-C250-30-6.0Eave strut C250 — 250×75×25mm — 3.0 BMT G550 Z350 — 6.0m
1
—
ES-C200-24-7.2Eave strut C200 — 200×75×25mm — 2.4 BMT G450 Z350 — 7.2m
1
—
ES-C230-24-7.2Eave strut C230 — 230×75×25mm — 2.4 BMT G450 Z350 — 7.2m
1
—
RC-C150-6.0Ridge cap C150 — 150×65×20mm — 1.5 BMT G450 Z350 — 6.0m
1
—
RC-C200-6.0Ridge cap C200 — 200×75×25mm — 1.9 BMT G450 Z350 — 6.0m
1
—

Structural connections in C and Z purlin systems require high-strength bolts to AS/NZS 1252:2016 (M12 and M16, Grade 8.8) for cleat-to-rafter and lap connections. Purlin-to-cleat connections use 12-14×20 mm hex-head self-drilling screws (Class 3 or Class 4 coating). Steel Source Australia supplies a complete range of structural bolts, nuts, washers and purlin screws for rollformed structural systems.

Technical Note

All bolts in purlin cleat connections must be Grade 8.8 minimum per AS/NZS 4600:2018. Galvanised bolts (Class 4.6 or 8.8 HDG) are required in C3 and above environments. Do not use zinc-plated bolts in exposed or coastal applications.

SKUDescriptionQTYLength (mm)
SB-M12-50-88-HDGBolt M12×50mm — Grade 8.8 — hot-dip galvanised — with nut & washer
1
—
SB-M12-75-88-HDGBolt M12×75mm — Grade 8.8 — hot-dip galvanised — with nut & washer
1
—
SB-M16-50-88-HDGBolt M16×50mm — Grade 8.8 — hot-dip galvanised — with nut & washer
1
—
SB-M16-75-88-HDGBolt M16×75mm — Grade 8.8 — hot-dip galvanised — with nut & washer
1
—
SB-M12-NUT-HDGNut M12 — Grade 8 — hot-dip galvanised
1
—
SB-M16-NUT-HDGNut M16 — Grade 8 — hot-dip galvanised
1
—
SB-M12-WASH-HDGWasher M12 — structural — hot-dip galvanised
1
—
SB-M16-WASH-HDGWasher M16 — structural — hot-dip galvanised
1
—
PS-1214-20-C3Purlin screw 12-14×20mm hex head — Class 3 — box 100
1
—
PS-1214-20-C4Purlin screw 12-14×20mm hex head — Class 4 — box 100
1
—
PS-1214-25-C3Purlin screw 12-14×25mm hex head — Class 3 — box 100
1
—
PS-1214-25-C4Purlin screw 12-14×25mm hex head — Class 4 — box 100
1
—

Applicable Standards

Compliance & Standards

AS/NZS 4600:2018

Cold-Formed Steel Structures

Primary design standard for C and Z purlins. Governs span tables, lap lengths, bridging requirements, cleat design and connection capacity.

AS/NZS 1397:2021

Metallic Coated Steel Sheet & Strip

Specifies Z350 zinc coating mass (350 g/m² total both sides) and mechanical properties for G450 and G550 high-tensile steel grades.

AS/NZS 1170.2:2021

Wind Actions

Determines design wind pressures for purlin and girt design. Wind region (A–D) and terrain category govern the design wind speed.

AS/NZS 1252:2016

High-Strength Structural Bolts

Specifies Grade 8.8 bolts for structural connections in purlin cleat and lap connections.

AS 3566.2:2002

Self-Drilling Screws — Corrosion Resistance

Governs Class 3 and Class 4 coating requirements for purlin screws in external and coastal applications.

NCC 2022 Vol. One

National Construction Code

Section B (Structure) performance requirements for structural members in Class 2–9 buildings, including deflection limits and load combinations.

C PurlinsZ PurlinsEave StrutsWall GirtsBridging ChannelSag RodsPurlin CleatsC100C150C200C250Z150Z200Z250G450 High-TensileG550 High-TensileZ350 Zinc Coating1.5 BMT2.0 BMT2.5 BMT3.0 BMT6.0m7.2m9.0m12.0mAS/NZS 4600AS/NZS 1397AS/NZS 1170.2Cold-Formed SteelStructural PurlinsIndustrial BuildingsCommercial BuildingsAgricultural ShedsSteel Frame Buildings

Need a Quote?

Add items to your enquiry cart and submit — or call our team for project pricing on C and Z purlins, bridging and cleats.