Steel Source Australia
41+ SKUsAS/NZS 4600NASH Pt 1Steel-MAX™ System

Steel Frame
Flooring Systems

Residential Floor Framing System — cold-rolled C-Joists and C-Bearers with Steel-MAX™ FCB3 brackets, extended bearer brackets and lateral end restraints. Spans 3.2 m to 6.2 m at 450 mm centres; extended bearers to 8.0 m. Suitable for Class 1a dwellings per NCC. Australia-wide supply.

AS/NZS 4600 & NASH Pt 1

Designed to AS/NZS 4600 Cold-formed Steel Structures and the NASH Residential & Low-rise Steel Framing Standard Part 1.

Spans 3.2 m – 6.2 m

C-Joists span 3.2 m to 6.2 m at 450 mm centres. Extended bearer options available to 8.0 m.

G550 / G450 Z350 Galvanised

550–450 MPa yield strength with Z350 zinc coating (350 g/m²) per AS1397 for long-term sub-floor durability.

Steel-MAX™ System

Complete system: C-Joists, C-Bearers, FCB3 brackets, extended bearer brackets, lateral end restraints and fasteners.

Design Limitations: The Residential Floor Framing System is suitable for Class 1a dwellings (NCC) within the scope of AS4055. Floor live load exceeding 1.5 kPa (2.0 kPa for balconies) or concentrated loads over 1.8 kN require engineering calculations. Not suitable for heavy items (water beds, water tanks, pianos, heavy gym equipment) or applications within 1 km of aggressive coastal/industrial environments without ZAM® finish. Minimum ground clearance 400 mm. Contact us for engineering advice.
Technical Reference

Steel Floor Framing — Standards & Specifications

The Residential Floor Framing System is designed and manufactured to current Australian Standards. The following reference data supports engineers, certifiers and builders specifying cold-formed steel floor systems for residential construction.

Applicable Standards

StandardTitleApplication
AS/NZS 4600Cold-Formed Steel StructuresDesign of all C-Joist and Bearer members
AS1397Continuous Hot-Dip Metallic Coated Steel Sheet & StripZ350 zinc coating specification for joists and bearers
NASH Standard Pt 1Residential and Low-rise Steel Framing — Design Criteria 2005Primary design standard for the floor framing system
NCC Vol. 2National Construction Code — Class 1a DwellingsPerformance requirements; system suitable for Class 1a only
AS4055Wind Loads for HousingDesign limitation: building must conform to Clause 1.2
AS3566Self-Drilling Screws for Building & ConstructionClass 2 (sheet flooring, internal) / Class 3 (connections)
NCC Vol. 2 Pt 3.4.1Sub-floor Ventilation RequirementsVentilation details for sub-floor clearance compliance

Materials Specification

ComponentGradeMin. YieldBMT RangeCoating
C-Joists (light)G550550 MPa1.0 mmZ350 per AS1397
C-Joists (heavy) / C-BearersG450450 MPa1.2 – 2.4 mmZ350 per AS1397
FCB3 Brackets / AccessoriesG300 / G450300 – 450 MPapressed steelMin. Z275
Extended Bearer BracketsG300 / G450300 – 450 MPapressed steelMin. Z275
Lateral End RestraintsG300300 MPapressed steelMin. Z275
ZAM® option (adverse envs)ZAM®—as per sectionZAM® zinc-aluminium-magnesium

Span & Performance Reference — Steel Frame Floor System

Based on cold-formed steel floor framing technical data. Confirm with engineer for your specific project.

ParameterValue / RequirementNotes
C-Joist span range3.2 m – 6.2 mAt 450 mm centres; custom cut to nominated length ±10 mm
Extended bearer spanUp to 8.0 mExtended bearer bracket required; connections by building designer
Joist spacing450 mm centresStandard residential spacing per NASH Pt 1
Design live load1.5 kPa (residential)2.0 kPa for balconies; >1.5 kPa requires engineering calculations
Concentrated load limit1.8 kN maxLoads exceeding 1.8 kN require engineering calculations
Deflection limitSpan/500 and 12 mm maxUnder service loads per NASH Pt 1
Min. ground clearance400 mm150 mm localised (within 2 m of ventilated wall) on sloping sites
Coastal exclusion zone>1 km from aggressive environmentsZAM® finish available for adverse/coastal environments
Flooring substrateParticle board or plywoodMin. modulus of elasticity E = 3 GPa; glue and screw recommended
ScopeClass 1a dwellings (NCC)Single occupancy residential; AS4055 Clause 1.2 limitations apply

Key Technical Facts

C-Joists and Bearers: cold-rolled from G550 (1.0 mm) or G450 (1.2–2.4 mm) steel with Z350 zinc coating per AS1397
Steel-MAX™ FCB3 brackets connect C-Joists to C-Bearers — all connections must resist gravity, lateral and wind loads
C-Joists must be used as an in-plane system between bearers — joist-on-bearer configuration is not recommended
All fasteners must comply with AS3566: Class 2 for sheet flooring (internal only), Class 3 for all framing connections
Fasteners must not be positioned within 15 mm of any metal edge; gluing and screwing all sheet floors is recommended
ZAM® finish available for adverse environments — standard Z350 not suitable within 1 km of aggressive coastal/industrial sites
Sub-floor ventilation must meet NCC Vol. 2 Part 3.4.1; minimum 400 mm ground clearance required
Tested by University of Technology Sydney, James Cook University Cyclone Testing Station, University of Sydney and CSIRO
C-JoistC-BearerSteel Floor FrameResidential Floor FramingC90C150C200C250G550 SteelG450 SteelZ350 Zinc CoatingZAM® Coating1.0 BMT1.2 BMT1.6 BMT2.0 BMT2.4 BMTSteel-MAX™ FCB3 BracketJoist HangerBearer CleatClass 2 ScrewsClass 3 ScrewsAS/NZS 4600AS1397NASH StandardNCC Vol. 2AS4055AS3566Sub-Floor VentilationClass 1a DwellingWind Region N1–N6UTS TestedJCU Cyclone TestedCSIRO TestedCold-Formed Steel FloorNon-Combustible Floor FrameTermite ResistantRot ResistantLightweight Floor Frame

Need a Floor Frame Quote?

Add products to your enquiry list and submit — or contact us directly for custom-cut C-Joist and Bearer packages, extended bearer options or large project pricing.